| Measurement
Uncertainty MS09/MI16 Series: |
fullscale temperatures
< 1500°C: 0.3% of measured value in
°C + 1°C fullscale temperatures <
2500°C: 0.5% of measured value in °C |
| Measurement
Uncertainty MI18 |
0.4% of measured value in °C
+ 1°C or 2°C, whichever is greater |
| Repeatability
MS09/MI16 Series |
0.1% of measured
value in °C + 1°C |
| Repeatability
MI18 Series |
0.2% of measured value in °C
+ 1°C or 1,6°C, whichever is greater |
| Exposition Time
t90 |
1 ms with dynamic
adaptation at low signal levels, adjustable
up to 10 s |
| Analog Output
Signal |
0 or 4 – 20 mA selectable,
500 ¥Ø max. load |
| Digital Interface |
either RS 232
or RS 485 max. 57,6 kBd (standard supply),
Profibus (optional) |
| Temperature
Resolution |
analog < 0.1% of adjusted temperature
range, digital 0.1°C |
| Ambient Temperature
Range |
Pyrometer: operation
-10 – 70°C, storage -20 –
70°C, Fibre Optic Cable and Lens: 0-250°C |
| Power Supply |
24 V AC/DC (12 – 30 V AC/DC),
AC: 48 – 62 Hz, max. 2 VA |
| Isolation |
power supply,
analog and digital output are galvanically
isol. against each other and against housing |
| Housing and
Rating |
extruded aluminium profile, IP
65 per DIN 40 050 |
| Weight |
500 g |
| CE Label |
according to EU directives for
electromagnetic immunity |
| Laser Pointer |
(optional) 650
nm, < 1 mW, class II per IEC 60825-1-3-4 |
| Camera Modul |
PAL or NTSC |
| Video Signal |
isolated BAS
signal about 1 VSS at 75 ¥Ø, CCIR standard,
50 Hz |
| Resolution |
black/white 628 x 582 pixel |
| Field of View |
about 14% x
10% of focused distance |
| Signal Port |
Cinch connector with SCART adapter
connected to cable assembly (accessory) |
| Date, Time |
real time clock
with 5 year buffer |
| Image Overlays |
reticle, model no. or text of
your choice, max. 12 characters, time or date,
temperature and emissivity |